    How many deep freezers can run off one 15A circuit?
    I have an upright deep freezer that is standard fridge size and a chest style freezer that is 50 in wide and want to run them off the same 15 A circuit, would this be a problem?


    {threads merged}
    Stratmando's Avatar
    Stratmando Posts: 11,188, Reputation: 508
    Uber Member
     
    #2

    May 2, 2010, 07:06 PM

    Personally I would have each on its own breaker, with both compressors kicking in at the same time, may trip breaker.
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #3

    May 2, 2010, 07:50 PM

    I agree. You should tell us the current requirements for each to be sure but 2 units on one 15amp will likely blow.
    Randyjazz's Avatar
    Randyjazz Posts: 6, Reputation: 1
    New Member
     
    #4

    May 4, 2010, 08:47 AM

    THanks guys but I only have one circuit remaining to run both and I've read that when the compressor kicks in, it only draws 2-3 amps. Do either of you know if this is true?
    Randyjazz's Avatar
    Randyjazz Posts: 6, Reputation: 1
    New Member
     
    #5

    May 4, 2010, 08:49 AM
    How many deep freezers can run off one 15A circuit?
    I have an upright deep freezer that is standard fridge size and a chest style freezer that is 50 in wide and want to run them off the same 15 A circuit, would this be a problem?
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #6

    May 4, 2010, 08:55 AM

    Yes, a post 1986 freezer could use 2-3 amps when running but double that on start up. Can you tell us what's on the tags of both freezers in either watts or amps required?
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #7

    May 4, 2010, 08:57 AM

    Why the new post, we are the same guys here as yesterday. Tell us the wattage or amps required for both freezers. On start up they each could pull up to 10 amps.
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #8

    May 4, 2010, 02:02 PM
    I suggest that you read and follow the manufacturers instructions for each unit. I suspect that both will state that each requires a separate circuit.

    Chances are for both to start at the same time is very low. Take the chance and ignore the advice of having both on separate circuits, all may be fine for who knows how long, till one day they both happen to start at the same time, and the breaker will trip.

    Then you can take the advice and put each on it's own circuit.
    Stratmando's Avatar
    Stratmando Posts: 11,188, Reputation: 508
    Uber Member
     
    #9

    May 4, 2010, 06:21 PM

    If the wiring is in conduit, you can pull extra wires and use a double breaker(not to be confused with a 2 pole breaker).
    2 breakers in the space of 1.
    Randyjazz's Avatar
    Randyjazz Posts: 6, Reputation: 1
    New Member
     
    #10

    May 4, 2010, 07:19 PM

    The one freezer says 4 amps, the other is sitting in a friend's garage waiting to be picked up, it's a year old and about the same size as the 4 amp which is about 12 years old. Assuming it's 4 amps or less, is it safe to say it should work off one circuit?
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #11

    May 4, 2010, 07:24 PM

    Nope, not yet, 4 amps is running amps and we are guessing about the other one. $ amps running could ba as much as 8 staring amp. If they were identical then they could blow a 15 amp breaker if they kicj in at the same time. TK mentioned earlier that both at once would be a very slight chance but it would eventually happen. If you were not in the area to notice the breaker blew you lose. Is you wire in conduit or is it cable or BX?
    Randyjazz's Avatar
    Randyjazz Posts: 6, Reputation: 1
    New Member
     
    #12

    May 6, 2010, 06:31 PM

    So one is 4 amps and the other is 3 amps, will this work?
    Stratmando's Avatar
    Stratmando Posts: 11,188, Reputation: 508
    Uber Member
     
    #13

    May 6, 2010, 09:39 PM

    Do you ever have power outages where you live?
    It MAY work for many years like that, can you tell us if it is in conduit or not?
    I would have on separate if possible, One could develop a problem and cause the breaker to blow, losing food to 2 freezers.
    Randyjazz's Avatar
    Randyjazz Posts: 6, Reputation: 1
    New Member
     
    #14

    May 7, 2010, 07:16 PM

    Occasional power outages, not sure on the conduit. How do you tell?
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #15

    May 7, 2010, 07:26 PM

    Conduit is a grayish steel pipe in which the wires are run. If you have several wires that are encased in PVC you have cable that

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Increasing from 15A circuit to 20A [ 4 Answers ]

Need your expertise, My living room and my bed room are on the same circuit breaker and they are under 15A load. Lately, I have more devices that connect to the receptacles in the living room, such as: Denon AVR-4308 XBox360 48 LCD TV Wii 500W HTPC

15A receptacles on 12/2 GFCI Circuit [ 5 Answers ]

I was just looking at some of the wiring that was done in my house when it was built in 2003. I have one GFCI Circuit that has 5 receptacles on it. On this, it is wired all with 12/2 to the garage first, where the receptacle is the GFI, then it runs 3 outdoor receptacles, and 1 in the basement. ...

Square D 15A Circuit Breaker [ 1 Answers ]

In my home, I have a Square D service panel. I am changing one of the circuit breakers from a standard breaker to a GFCI type (the circuit is outside). I could not find any 15A Square D breakers at any of my local stores (Home Depot, Lowe's and a few electrical supply stores). Most stores carry...

Maximum load on 15A circuit [ 5 Answers ]

What is the maximum load in watts, that will blow a fuse on a 15 amp household circuit?

How many lights on a 15A lighting circuit [ 3 Answers ]

Hi everyone! First post and thanks in advance, hopefully! I was wondering how many lights I can put on a 15A lighting circuit. I have a second floor that I want to put a (1) hall light, (3) closet lights, & (1) bedroom light. Would it be too much to put a bathroom vanity light and a vent...


View more questions Search