Ask Experts Questions for FREE Help!
Ask    ||    Answer
 
Advanced  
 

Ask QuestionsprogressAnswer QuestionsprogressBuild ReputationprogressBecome an Expert
 
Free Answers in 3 Easy Steps

Register Now
3 Steps

At Ask Me Help Desk you can ask questions in any topic and have them answered for free by our experts. To ask questions or participate in answering them you must register for a free account. By registering you will be able to:
  • Get free answers from experts in any of our 300+ topics.
  • Accept money for answers that you provide.
  • Communicate privately with other members (PM).
  • See fewer ads.

Home > Home & Garden > Appliances   »   GE Electric Range

 
Thread Tools Search this Thread Display Modes
Question
 
 
#1  
Old Oct 28, 2006, 04:26 PM
darroyos
New Member
darroyos is offline
 
Join Date: Oct 2006
Posts: 3
darroyos See this member's comment history on his/her Profile page.
GE Electric Range

Help! My electric Range is 3 years old. The range timer and clock are working,however the oven nor the surface units heat up. Does this sound like something I can repair myself or should I be calling a repair person?

Reply With Quote
 
     

Answers
 
 
Old Oct 28, 2006, 04:50 PM   #2  
Über Member
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,646
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
Sounds like somewhere, something isn't connected. Shut off the breaker, and open up the panel where the switch are. Poke around for a loose or broken wire.

To do simple checks like this you do need some tools. A test light, a meter, or a voltage detector might be the best place to start with. I came across the niftiest gadget for trouble shooting, a voltage detector. They work through the insulation of wires. There are several brands. I have a GB Instruments GVD-505A, less than $15 at Home Depot. Touch it to a hot wire, and the end glows red. Find the doodad that lights it on one side, and not the other, and you have the culprit. You do not have to open up housings and expose electrical contacts. You are looking at where your hand is, not where the meter is. Most people are capable of doing repairs and will get it going and not get hurt if they use a little sense. The voltage detector makes it even easier.

You are about the 4-5 one I suggested the voltage detector to. No, I do not own stock in GB Instruments. It is just that I find mine really handy and don't know how I did without one for so long.

You should be able to fix it as long as it isn't a modern abomination with digital controls. Even then, you can replace an expensive module as well as a tech.
  Reply With Quote
 
     
 
 
Old Oct 28, 2006, 08:22 PM   #3  
New Member
darroyos is offline
 
Join Date: Oct 2006
Posts: 3
darroyos See this member's comment history on his/her Profile page.
Thank you soooo much. I will definitely get me a voltage detector. I will let you know what happens.
  Reply With Quote
 
     
 
 
Old Oct 28, 2006, 08:39 PM   #4  
Senior Member
RichardBondMan is offline
 
Join Date: Oct 2006
Location: Alabama
Posts: 833
RichardBondMan See this member's comment history on his/her Profile page.
I was friends with an appliance repairman. he has told me many times that these new "digital" (guess your clock display is digital ?), ovens work much like a computer, many small connections soldered onto a board, and when something like you describe happens, best to replace the board, quite expensive to do this.

Comments on this post
labman agrees: ''a modern abomination with digital controls.''
  Reply With Quote
 
     
 
 
Old Oct 28, 2006, 10:26 PM   #5  
Full Member
andrewcocke is offline
 
Join Date: Oct 2006
Location: The Attic
Posts: 440
andrewcocke See this member's comment history on his/her Profile page.
Quote:
Originally Posted by labman
Sounds like somewhere, something isn't connected. Shut off the breaker, and open up the panel where the switch are. Poke around for a loose or broken wire.

To do simple checks like this you do need some tools. A test light, a meter, or a voltage detector might be the best place to start with. I came across the niftiest gadget for trouble shooting, a voltage detector. They work through the insulation of wires. There are several brands. I have a GB Instruments GVD-505A, less than $15 at Home Depot. Touch it to a hot wire, and the end glows red. Find the doodad that lights it on one side, and not the other, and you have the culprit. You do not have to open up housings and expose electrical contacts. You are looking at where your hand is, not where the meter is. Most people are capable of doing repairs and will get it going and not get hurt if they use a little sense. The voltage detector makes it even easier.

You are about the 4-5 one I suggested the voltage detector to. No, I do not own stock in GB Instruments. It is just that I find mine really handy and don't know how I did without one for so long.

You should be able to fix it as long as it isn't a modern abomination with digital controls. Even then, you can replace an expensive module as well as a tech.
I second that. I have a fluke volt pen. I wouldnt take anything for it. Very handy, and worth its weight in gold.

Comments on this post
labman agrees: There is no substitute for the very best if you are making your living with it, and risking your life daily on it.
  Reply With Quote
 
     
 
 
Old Oct 29, 2006, 05:43 PM   #6  
New Member
darroyos is offline
 
Join Date: Oct 2006
Posts: 3
darroyos See this member's comment history on his/her Profile page.
I purchased a volt detector today and have tested the lines. I notice that the detector light goes on however as I run it along the wire there seems to be certain breaks. The lights do not light on some parts of the wire. I have also tested the wall outlet. My range has a three prong power cord so outlet is the same, when tested with the volt detector only one of the three openings of the outlet is voltage detected. Is this normal?

P.S. Thanks to all who have answered.
  Reply With Quote
 
     
 
 
Old Oct 29, 2006, 07:00 PM   #7  
Über Member
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,646
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
It sounds like one leg is dead. You have 2 legs, incoming hot wires each 120 volts to ground, but opposite phases, one 120 volts above and the other below. Being AC, they alternate 60 times a second. There is also a neutral that is grounded. Power flows out a hot wire and can connect to either the neutral for 120 volts or the other hot wire for 240 volts. Only one leg feeds the lights and controls. If it is hot, the lights and controls will work, but not the heating elements.

If your stove is wired like mine, it is time to call an electrician. A few last straws. Turn the breaker all the way to off, and back on. Doubt that will help, but try it. Older houses had a separate little fused disconnects for 240 volt service. If there is one for the stove, shut it off and open the cover. If you see a blown fuse, you are in luck. Replace it, and the stove should work. If both fuses look OK, turn the power back on and touch your voltage detector to both ends of both. If one end of one doesn't light it, again, bingo, a bad fuse. Shut the power off again and replace it.
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
Electric Force and Electric Field?
(1 replies)
white powder under electric range burner
(4 replies)
Range
(1 replies)
wifi range
(0 replies)
tip dia and pressure range and gas flow range
(0 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 12:32 AM.