Dryer heating, but takes 120 minutes for average load
We replaced the heating element and that is not the problem. Good airflow coming out back of dryer,vent hose and lint traps are clear, and coils heating up. Help! What else could be the problem?
|
|
|
Senior Member
|
|
Jun 18, 2007, 07:28 PM
|
|
I will venture a guess that's it's a stackable unit, one with the washer on the bottom with a dryer on top of the washer, a one piece unit. Am I correct? If so, it probably runs on 110V not the usual 220V and those dryers take much longer to dry normally.
|
|
|
New Member
|
|
Jun 18, 2007, 07:47 PM
|
|
Originally Posted by lmelkins1
We replaced the heating element and that is not the problem. Good airflow coming out back of dryer,vent hose and lint traps are clear, and coils heating up. Help! What else could be the problem?
No, its not a stackable and was working fine up until about 6 weeks ago.
|
|
|
Senior Member
|
|
Jun 19, 2007, 04:17 AM
|
|
Let's see if a trained appliance tech has a solution or idea. I am stumped.
|
|
|
Ultra Member
|
|
Jun 19, 2007, 05:11 AM
|
|
Have you check where vent hose exits house. Many times it get clogged there or birds will build a nest there. I does sound a lot like a venting problem. Also check to be sure the flexable vent is not pinched anywhere. One easy test for this would be to disconnect vent hose from back of dryer and run a load. Doest it dry in less time? If yes, Problem is venting. I know you said it is all clear but double check it. Also , confirm there is 220V at the outlet and not 110
|
|
|
Ultra Member
|
|
Jun 19, 2007, 05:26 AM
|
|
Also,if the door seal can wear out and leak, which can disrupt proper air flow. Check the area where the blower motor is. Is it all free of lint. What model is this?
|
|
|
New Member
|
|
Jun 19, 2007, 08:27 AM
|
|
It's a Maytag LDE490
I will remove the vent hose and run a load and see what happens... The dryer is in the basement and the vent hose runs into the wall and I assume it filters outside. I did find a opening on the outside of the house, but could not feel any air coming out of it. (but it is quite a distance away from the actual dryer). I will try the above today and report my findings! I will also check out the door seal.
Thank you!
|
|
|
Ultra Member
|
|
Jun 19, 2007, 08:37 AM
|
|
If dryer is running and no air is exit at the outside you have found the problem. The solution is to find he restriction. It will be somewhere between the dryer and out side. You may have to remove the cover on outside of house only to find it clogged there. Good luck. Post back with results as it may help others.
|
|
|
New Member
|
|
Jun 19, 2007, 08:41 AM
|
|
There is no cover on the outside of the house, which concerns me about critters and things climbing in. But will still run a load w/o the vent hose to make sure.
|
|
|
Ultra Member
|
|
Jun 19, 2007, 08:58 AM
|
|
I'd say you found your problem. You need to get a dryer cover for it. Critters do like to get in there. Also birds love to build nest. Seen it many times
|
|
|
New Member
|
|
Jun 19, 2007, 11:11 AM
|
|
Well, I took the vent off and a load dried in a normal cycle. So there is a blockage somewhere between the wall and the outside of the house. This is no easy task as I'm not sure where the vent is (as the vent from the dryer goes into a wall - strange design) and you can't see where the tubing starts in the wall that eventually leads outside. I expect the tubing is at least 15-20 feet long going from the basement to upstairs. I may have to call someone to clear it out.
Thanks for all the help :-).
|
|
|
Ultra Member
|
|
Jun 19, 2007, 12:19 PM
|
|
Get it clean and you'll be set to go. Think how much extra your electric bill is with the dryer running twice as long. The fix will be paid for in no time at all. Glad I could help
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
Pc will load XP PRO but .takes probably three to fours hours
[ 1 Answers ]
Foxconn mbd up to 3 Year Warranty available
Model 6100K8MA-RS Retail Boxed Main board
Supported CPU
CPU Socket Type AMD Socket 939 Socket Dual Core support - OEM
AMD ATHLON 64 3700+ PROCESSOR INCLUDED
Heatsink with Fan included
Motherboard Supports Maximum CPU Support any 939pin cpu in...
3 phase 208 volt/120 volt .load
[ 1 Answers ]
I am trying to hook up a commercial espresso machine which has a 220 line. My existing electrical box is a 3 phase 208 volt/120 volt. Would this be sufficient to handle this??
Thank you
Windows takes 40 minutes to load.
[ 13 Answers ]
For about the past month, I've had problems with Windows loading. At first, it was random and now it seems like it is happening more frequently. I'm at the point where I don't want to turn my computer off for fear of it never loading again. What happens is after it goes into "standbye" or when...
Computer takes up to 5 minutes shutting down
[ 1 Answers ]
Hi, I have problems with my laptop shutting down quickly. If I click start>shut down, most of my time is spent waiting for the shutdown dialog box, the one which asks to restart-logoff-shutdown. My alternate is ctrl+alt+del and shut down from the menu there, but while I don't have to wait for the...
View more questions
Search
|