  Answer this Question    Ask about Heating & Air Conditioning    Ask about another Subject  
 

Holvinpr
Jan 22, 2009, 11:09 AM
I bought a brand new central a/c and gas furnace about 2 years, i never have to use the heater until this winter. My problem is when I tried to turn on the heater, i did see the electronice ignition comes light but after few seconds is shutting off. I noticed a blinking red light on the control pannel, i verified what that means in the error codes and is stating error code #4"Ground error" what that means can i repair the problem myself? or i have to call for service, also the HVAC tech who intalled my a/c and furnace also installed a new thermostat. He was a subcontractor so i cant find him to repair what he installed any advace, please help my kids are freezing.

eschuen
Jan 24, 2009, 03:06 PM
2 quick things you can check. Is the line voltage wired correct? Sometimes a netural and ground get crossed by an untrained service tech. Next see if you have a green wire coming from the board to a ground source. Polarity is very important to the board, so if the netural and ground are crossed somewhere it's going to be the wrong polarity. The board has to have a good ground to operate correctly. It may be just tightening a loose ground wire.