homerunbetty Dec 5, 2008, 06:12 PM We have an electric Coleman central heater in our attic. The pilot light will not light up. Our gas water heather is working just fine as we have hot water. But we cannot get the pilot light on our central heater to work. The heater is 8 years old. I removed the panel to the heater and cannot locate any other information to provide as far as the model number or serial number is concerned.
wmproop Dec 5, 2008, 06:21 PM if its a electric furnace as stated,it won`t have a pilot light
mygirlsdad77 Dec 5, 2008, 06:28 PM wmproop is exactly right. Can you please clarify as to whether you have an electric or gas furnace.
As far as i know, most coleman furnaces are for modulars and trailer houses, never seen one in an attic. Probably just the area i live as to why ive never seen this setup. Hopefully i learn something here today. Lets hear some input guys.
homerunbetty Dec 5, 2008, 06:40 PM Ok. That goes to show you how much I know about the heater. I guess I explained myself wrong. Our central heater lights electrically. It is not lighting to heat our home. I found the original paper with a product no. of G8C10016MUCC11A and was installed 6/15/01. :(
mygirlsdad77 Dec 5, 2008, 07:09 PM okay, are you sure its a coleman? If its the coleman im used to seeing, it will have a glow plug(instead of spark ignition) and there will be no pilot. the glow plug will ignite main burner.
Is there any way you could take a picture of the furnace and post it here? If my thinking is right, this should be a fairly easy to trouble shoot. Most likey a burnt out glow plug, but it could be a vent problem, or inducer problem, or faulty pressure switch.
homerunbetty Dec 5, 2008, 07:43 PM http://i36.tinypic.com/1jxffc.jpg
http://i37.tinypic.com/2lctjqv.jpg
http://i38.tinypic.com/28grv4m.jpg
http://i37.tinypic.com/34o915w.jpg
mygirlsdad77 Dec 6, 2008, 02:03 PM sorry, cant really see the pics to well. But i would say its not what i had pictured in my mind.
It appears there is a pilot tube, so i was wrong about the no pilot.
wmproop Dec 6, 2008, 02:07 PM wow guess I`m getting old,,, mygirldsdad can see much better than I can
KC13 Dec 6, 2008, 02:10 PM Don't see a pilot tube, and only see two wires on the gas control. This is typical of direct ignition. Observe the operating sequence for a couple of minutes from start-up, listen for clicks and/or hissing sounds and post back.
mygirlsdad77 Dec 6, 2008, 02:12 PM third pic down. looks like a pilot tube at top right of pic, just the way it is bent in a loop makes me think it may be a tube instead of a wire(probably wrong), My eyes definatley leave something to be desired, especially with these pics.
KC13 Dec 6, 2008, 02:16 PM Looks too small for a pilot tube, compared to the other wires in the pic...
mygirlsdad77 Dec 6, 2008, 02:20 PM could be a 1/8 tube instead of 1/4. but like i said, im most likely wrong. all i really see is alot of dark with shades of color.lol
KC13 Dec 6, 2008, 02:25 PM 1/8"...you mean like Reznor unit heaters...with the "convenient break-off feature"...LOL
mygirlsdad77 Dec 6, 2008, 02:30 PM exactly, or most new water heaters and gas fireplaces. I quess ive never actually seen a 1/8 pilot tube on a gas forced air furnace. Id actually be surprised to see a pilot on an 01 model.
homerunbetty Dec 6, 2008, 02:40 PM I turned everything off and turned the switch to off and waited 5 minutes. I clicked it back on and turned everything else back on and it is supposed to light. When I did this, it sounds like it wants to come on, but nothing happens. It isn't making any noise when I turn it on.
MarkwithaK Dec 6, 2008, 02:45 PM 1/8"...you mean like Reznor unit heaters...with the "convenient break-off feature"...LOL
Hey that's an upgrade. You pay extra for that feature. :p
KC13 Dec 6, 2008, 02:46 PM Normally, the induced-draft blower starts first, establishing a combustion draft and engaging a pressure switch or centrifugal switch. if the inducer does not run it may be stuck due to a seized motor or an obstruction in the inducer housing/outlet.