FRANKKINCAID
Oct 23, 2008, 02:15 PM
my bryant furnance model 100-394u wont light up.the gas is on,the pilot is on but it still wont light. last year i put a new hunter thermostat and it worked all winter but this year it wont start any advise
FRANKKINCAID Oct 23, 2008, 02:15 PM my bryant furnance model 100-394u wont light up.the gas is on,the pilot is on but it still wont light. last year i put a new hunter thermostat and it worked all winter but this year it wont start any advise wmproop Oct 23, 2008, 04:14 PM wow,,,,if you got a year out of a hunter tstat,consider your self lucky,,they are junk T-Top Oct 23, 2008, 06:16 PM Check to see if you have 24v at the gas valve(when the thermostat is calling for heat). If you dont have 24v, jump from R to W on the low voltage. If no flame or 24v on the gas valve after that make sure you have a 115v to power the furnace and transformer. Make sure you put the gas valve back to on after lighting the pilot. This unit has to be around 30 years old. Copyright ©2005-, Ask Me Help Desk
|
||||||||